<-- Back to Products

Aviation and Meteorological - Wind/Altimeter Digital Display System (WADDS)

Wind/Altimeter Digital Display System (WADDS) PEP8910-1 + PEP8901-2

Technical Specifications - WADDS-STU

Technical Specifications - WADDS-CDU


Wind/Altimeter Digital Display System (WADDS)

Wind/Altimeter Digital Display System (WADDS) PEP8910-1 + PEP8901-2

The PEPL WADDS system provides real-time distribution of current Altimeter Setting Indicators (ASI) and wind information. The system consists of a wind sensor, Sensor Transmitter Unit (WADDS-STU PEP8910-1) and Console Display Unit (WADDS-CDU PEP8901-2). The WADDS-STU processes wind sensor information, measures atmospheric pressure and converts measurements into ASI values for display via the WADDS-CDU.

WADDS-STU PEP8910-1 WADDS-CDU PEP8901-2

WADDS-STU PEP8910-1

WADDS-CDU PEP8901-2

  • for aviation (runway and aerodrome) weather reporting applications
  • real-time distribution of current Altimeter Setting Indicators (ASI) and wind information
  • wind sensor comprised of an anemometer and remote processor
  • WADDS-STU - Sensor Transmitter Unit
  • WADDS-CDU - Console Display Unit

The wind sensor transmits wind information to the remote processor which averages the vector components over pre-set intervals and sends this to the STU. The STU processes the wind information, measures atmospheric pressure and converts measurements into ASI values. The STU transmits the ASI information to the CDU for display.

Technical Specifications - WADDS-STU

Equipment Name:WADDS-STU
Model:PEP8910-1
Magnetic variation adjustment range:+/- 0-99° east or west
Site elevation range:0-2400 metres
ASI null offset:+/- 0.06 inHg (0.001 in increments)
Measurement modes:wind only, ASI only (single or dual transducer), wind and ASI (single or dual transducer)
Display viewing angle+/- 60° (horizontal and vertical)
Readabilitytotal darkness to bright sunlight
ASI range27 to 32 inHg
ASI accuracy+/- 0.05%
Wind speed0-99 knots
Wind gust15-99 knots
Communications ports20mA current loop, RS232x2, RS422
Operating temperature+10°C to +40°C
Storage temperature-30°C to +55°C
Relative humidity40-80%
Operating altitudesea level to 2400 metres
Non-operating altitudesea level to 15000 metres
Dimensions482.6Wx177.8Hx430.0D mm
Weight8.64kg
Crated weight11.82kg
Installation482.6mm (19") rack mount

Technical Specifications - WADDS-CDU

Equipment Name:WADDS-CDU
Model:PEP8901-2
Display viewing angle+/- 60° (horizontal and vertical)
Readabilitytotal darkness to bright sunlight
ASI range27 to 32 inHg
ASI alarm indicators<29.00, <29.93, >30.99 inHg
Wind direction display accuracy+/- 5°
Wind speed range0-99 knots
Wind gust range15-99 knots
Operating temperature+10°C to +40°C
Storage temperature-30°C to +55°C
Relative humidity40-80%
Operating altitudesea level to 2400 metres
Non-operating altitudesea level to 15000 metres
Dimensions241.3Wx177.8Hx228.6D mm
Weight2.73kg
Crated weight3.64kg
Installation482.6mm (19") rack mount or panel mount